Flexible Linear Electrode for AC Mitigation

Pipeline corrosion, caused by induced AC current, is attributed to high voltage AC power lines in close proximity to a pipeline system. The corrosion can be extremely aggressive, far exceeding the normal corrosion rate caused by corrosive soils. One of the most popular mitigation solutions is a linear grounding system that is installed in parallel to the pipeline.

Compared with bare copper and zinc ribbon, YUXI’s long-line “ribbon” is a superior grounding material that provides an effective electrical path to remove or discharge AC current from the pipeline to the ground. It is comprised of a bare stranded copper conductor encased in low resistance backfill with corrosion inhibitors, and then wrapped in a synthetic sock.

Compare

Description

—— Quality Copper Conductor ——

Our power cable delivers the required current over considerable distance without incurring substantial longitudinal voltage drop.

—— Evenly Backfill Filling ——

High performance calcined petroleum coke breeze is tightly pre-packaged and evenly distributed all around the copper conductor, serving as the active matrix in which the electro-chemical reactions take place.
MMO Linear Anode Backfill

—— Acid-resistant Braid Fabric Jacket ——

Our AC mitigation ribbon is prepackaged with porous, non-woven synthetic sleeve. This tough sleeve is sewn using a poly two or four-thread double interlocking stitch, which prevents the seam from separating during installation, or when stored in high temperature conditions.
Braid Fabric Sock

—— Reel Packing ——

Our AC mitigation ribbon can be packed on wooden or steel reel as required. It is normally installed right from the factory provided reel into the trench for easy transportation.

—— Practical Application ——

Our AC mitigation electrode is commonly applied to pipeline grounding systems or structure that are subject to AC interference. It is normally installed parallel to the pipeline through trenching, plowing or directional drilling.
● Prevent voltage spikes during fault conditions
● Reduce AC-induced corrosion
● Maintain AC step and touch potentials to protect personnel from shock hazards

Flexible Linear Electrode For AC Mitigation of Transmission Tower
AC Mitigation Anode Parallel with Pipelines
Category

AC Mitigation Electrode

Copper Conductor Type

#1/0 AWG, #2 AWG, #6 AWG

Fill Material

Calcined Petroleum Carbon Backfill

Sock Material

Synthetic Fabric

Braiding Material

Polypropylene Filament

Working Temperature

Min. -18°C (0°F)

Applicable Environment

Sand, Soil

Application

Pipeline

Specification

AC Mitigation Electrode Datasheet

Download

Product datasheet including basic product information, technical data, instructions for use and size options.